What it is
Graded particles are checked through standard thickness slots appropriate to each size fraction.
SANAS T1018
Public test guide
Measures the proportion of aggregate particles that are unusually thin compared with their size.
Plain-language explanation
The project specification controls the exact method and acceptance requirement.
Graded particles are checked through standard thickness slots appropriate to each size fraction.
Prepared aggregate fractions, standard flakiness gauge and balance.
The mass percentage of particles classified as flaky.
Controls particle shape because excessive flaky particles can affect compaction, strength and durability.
Typical test sequence
Separate the aggregate into size fractions
Gauge each fraction through the specified slots
Weigh flaky particles and calculate the index