What it is
A conditioned unit is weighed and its external volume is determined by measurement or the specified displacement method.
SANAS T1018
Public test guide
Measures the mass of a brick or masonry unit relative to its overall volume.
Plain-language explanation
The project specification controls the exact method and acceptance requirement.
A conditioned unit is weighed and its external volume is determined by measurement or the specified displacement method.
Representative unit, balance, dimensional tools and conditioning equipment.
Bulk density of the masonry unit.
Supports product classification, dead-load calculations and comparison of manufacturing consistency.
Typical test sequence
Condition and weigh the unit
Determine its volume by the specified method
Calculate mass per unit volume
Request this service