What it is
Water is allowed to pass through a saturated specimen while the drop in water head in a standpipe is measured over time.
SANAS T1018
Public test guide
Measures how readily water flows through relatively low-permeability soil.
Plain-language explanation
The project specification controls the exact method and acceptance requirement.
Water is allowed to pass through a saturated specimen while the drop in water head in a standpipe is measured over time.
Prepared specimen, permeameter, standpipe, water supply, timing device and temperature measurement.
The coefficient of permeability under the test condition.
Used for drainage, seepage, liner, embankment and groundwater-related design assessments.
Typical test sequence
Prepare and saturate the specimen
Establish the starting water head
Measure head reduction with time and calculate permeability
Request this service